AffiVET® Mycoplasma Gallisepticum (MG) Antibody ELISA Test Kit

Veterinary Diagnostics • ELISA Test Kits

AffiVET® Mycoplasma Gallisepticum (MG) Antibody ELISA Test Kit

Indirect ELISA for the detection of Mycoplasma gallisepticum-specific antibodies in chicken serum and the assessment of flock antibody responses.

AffiVET Mycoplasma Gallisepticum MG Antibody ELISA Test Kit

Product image

Product Information

SKU AFG-VGS-37
Product Type Indirect ELISA Test Kit
Target Mycoplasma gallisepticum antibodies
Sample Type Chicken serum
Format 96-well microplate
Incubation 37°C
Detection Colorimetric, OD at 450 nm
Storage 2–8°C, protected from light
Shelf Life 12 months
Packaging: 96 wells per kit

Product Description

The AffiVET® Mycoplasma Gallisepticum (MG) Antibody ELISA Test Kit is an indirect enzyme-linked immunosorbent assay designed to detect antibodies against Mycoplasma gallisepticum in chicken serum.

The assay supports the assessment of antibody responses following MG vaccination in chicken flocks and can assist in the serological evaluation of exposure to Mycoplasma gallisepticum.

Using an antigen-coated 96-well microplate, the test detects specific antibodies through an enzyme-mediated colorimetric reaction. Optical density is measured at 450 nm, and sample results are evaluated using the sample-to-positive (S/P) ratio.

Intended Use

This kit is intended for:

  • Detection of Mycoplasma gallisepticum-specific antibodies in chicken serum.
  • Assessment of antibody responses following MG vaccination.
  • Serological monitoring of chicken flocks.
  • Supporting the serological evaluation of possible MG exposure in poultry.

Note: Antibody detection alone does not establish active infection. Results should be interpreted alongside clinical findings, flock history and other appropriate diagnostic tests.

Assay Principle

The kit is based on an indirect ELISA method. Microplate wells are pre-coated with MG antigen. When chicken serum containing specific antibodies is added, the antibodies bind to the immobilized antigen.

After washing away unbound components, an enzyme conjugate is added. Following another washing step, TMB substrate is introduced, producing a colorimetric reaction. The reaction is stopped using stop solution, and absorbance is measured at 450 nm.

MG Antigen-Coated Microplate
↓
Add diluted chicken serum
↓
Specific MG antibodies bind to coated antigen
↓
Washing and enzyme conjugate addition
↓
TMB substrate reaction
↓
Stop reaction and read OD at 450 nm

Kit Contents

No. Reagent / Component Quantity
1 MG antigen-coated microplate 1 plate (96 wells)
2 Enzyme conjugate 11 mL
3 10× concentrated washing buffer 100 mL
4 Substrate solution 11 mL
5 Sample dilution 100 mL
6 Stop solution 15 mL
7 Negative control 2 mL
8 Positive control 1.6 mL
9 Serum dilution plate 1 piece
10 Adhesive film 2 pieces
11 Instruction manual 1 piece

Materials Required but Not Provided

  • Micropipettes covering 0.5–10 µL, 10–100 µL and 100–1,000 µL ranges.
  • Disposable pipette tips.
  • 37°C incubator.
  • 500 mL measuring cylinder.
  • 96-well microplate reader.
  • Distilled or deionized water.
  • Bottle washer or microplate washing machine.

Sample Preparation

Collect chicken whole blood and prepare serum using standard laboratory procedures. The serum should be clear and free from visible hemolysis.

Serum Dilution

Dilute serum at a ratio of 1:99 using the supplied sample dilution buffer.

Example: Mix 5 µL of serum with 495 µL of sample dilution buffer.

Mix samples evenly before dispensing. Change pipette tips between samples and accurately record sample positions on the plate. Positive and negative controls are used without dilution, according to the supplied instructions.

Preparation of Washing Buffer

  1. Bring the concentrated washing buffer to room temperature before use.
  2. If salt crystals are visible, shake until they dissolve.
  3. Dilute the 10× concentrated washing buffer 1:10 with distilled or deionized water.
  4. The diluted washing buffer can be stored at 4°C for up to one week, according to the manufacturer's instructions.

ELISA Procedure

Follow the manufacturer's instructions carefully. The principal assay steps are summarized below.

  1. Sample loading: Add 100 µL of diluted serum to the designated sample wells. Add 100 µL of undiluted negative control to one well and 100 µL of positive control to each of two designated wells. Cover the plate and incubate at 37°C for 30 minutes.
  2. First washing: Remove the liquid and add 250 µL of diluted washing buffer to each well. Repeat the washing procedure 4–6 times. After the final wash, tap the plate on absorbent paper to remove residual liquid.
  3. Enzyme conjugate: Add 100 µL of enzyme conjugate to each well. Cover and incubate at 37°C for 30 minutes.
  4. Second washing: Repeat the washing procedure 4–6 times and tap the plate dry on absorbent paper.
  5. Substrate reaction: Add 100 µL of substrate solution to each well. Mix gently and incubate for 10 minutes at 37°C in the dark.
  6. Reaction termination: Add 50 µL of stop solution to each well. Measure the optical density within 10 minutes.
Measurement: Read absorbance at 450 nm, using 630 nm as the reference wavelength where applicable.

Results and Interpretation

Test Validity Criteria

The assay is considered valid when both control conditions are met:

  • Negative control OD (N) is less than 0.2.
  • Positive control mean OD (P) is greater than 0.5.

S/P Ratio Calculation

S/P = Sample OD ÷ Average Positive Control OD

Result Interpretation

S/P Value Interpretation
S/P < 0.2 Negative
S/P ≥ 0.2 Positive

Interpret results only when the validity criteria are satisfied. For diagnostic decisions, consider flock history, vaccination status and other relevant laboratory findings.

Precautions and Handling

  • Bring all reagents to room temperature and mix gently before use.
  • Store reagents at 2–8°C after use, following the product instructions.
  • Do not interchange reagents from kits with different lot numbers.
  • Avoid contamination of reagents during handling.
  • Protect the substrate solution from light and avoid contact with antioxidants.
  • Handle the substrate and stop solution carefully, as they may irritate skin and eyes. Wear appropriate personal protective equipment.
  • After opening the microplate pouch, return unused strips to the original bag with the desiccant and store at 2–8°C. Protect unused wells from moisture.
  • The serum dilution plate is disposable and must not be reused. Its maximum capacity is 300 µL per well.
  • Follow the recommended pipetting, incubation and washing times accurately.
  • Dispose of laboratory waste according to applicable safety and environmental procedures.

Storage and Stability

  • Storage temperature: 2–8°C.
  • Light protection: Store protected from light.
  • Shelf life: 12 months.
  • Package size: 96 wells per kit.

Applications

  • Poultry veterinary diagnostic laboratories.
  • Chicken flock serological monitoring.
  • Evaluation of antibody responses following MG vaccination.
  • Veterinary research involving Mycoplasma gallisepticum.
  • Poultry health and disease surveillance programs.

Related Research Keywords

Mycoplasma gallisepticum ELISA, MG antibody detection, poultry ELISA test, chicken serum antibody test, veterinary diagnostic ELISA, poultry disease surveillance, MG vaccination monitoring, indirect ELISA kit, avian mycoplasmosis research.

AffiVET® MG Antibody ELISA Test Kit

For product information, technical details and quotation requests, contact the product team.

Request a Quote

Product SKU: AFG-VGS-37

27th Nov 2026